Apc (ap7921b) Rack Pdu Switched 1u 16a 208/ 230v (8)c13 Ap7921b
SKU
246179
Brand
MPN
AP7921B
Warranty
Standard Manufacturer's Warranty
Availability
In stock
$1,714.00
Buy Now And Earn 1714 Reward Points!
AP7921BFeatures
Rack PDU, Switched, 1U, 16A, 208/230V, (8)C13
Switched Rack Power Distribution Units (PDUs) provide advanced load monitoring combined with remote on/off switching control of individual outlets for power cycling, delayed power sequencing, and outlet use management.
Includes : Installation Guide , Rack Mounting Brackets , User Manual
Switched Rack PDUFeatures & Benefits
Agility
- Rack-MountableIncludes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most - in the racks near the equipment.
- Single input power sourceSupply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.
- Wide range of input and output connectionsProduct family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Having a variety of inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.
Availability
- Integrates with StruxureWare Data Center ExpertAn IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
- Flash UpgradeableQuickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
- Network Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
- Remote Individual Outlet ControlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
- Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)
- Local Current Monitoring DisplayThe aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)
- Power DelaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
- Load indicator LEDIndicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.
Marketing Features
- Local Current Monitoring DisplayThe aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.
- Power DelaysAllows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependant on that unit will function properly.
- Alarm ThresholdsDefine alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.
- Remote Management CapabilitiesFull-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
- Remote Individual Outlet ControlRemotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).
Output
- Nominal Output Voltage208V , 230V
- Maximum Total Current Draw16
- Output Connections(8) IEC 320 C13 (Battery Backup)
Input
- Nominal Input Voltage200V , 208V , 230V
- Input frequency50/60 Hz
- Input ConnectionsIEC-320 C20
- Cord Length8.2ft ( 2.5meters )
- Acceptable Input Voltage200-240VAC
- Number of Power Cords1
- Load Capacity3680VA
- Maximum Input Current20A
- Regulatory Derated Input Current (North America)16A
Physical
- Maximum Height1.73inches ( 44mm , 4.4cm )
- Maximum Width17.5inches ( 445mm , 44.5cm )
- Maximum Depth4.25inches ( 108mm , 10.8cm )
- Rack Height1U
- Net Weight5.0lbs. ( 2.27kg )
- Shipping weight7.6lbs. ( 3.45kg )
- Shipping Height2.75inches ( 70mm , 7.0cm )
- Shipping Width18.5inches ( 470mm , 47.0cm )
- Shipping Depth13.5inches ( 343mm , 34.3cm )
- ColorBlack
Environmental
- Operating Environment32 - 113 °F ( 0 - 45 °C )
- Operating Relative Humidity0 - 95 %
- Operating Elevation0-10000ft ( 0-3000meters )
- Storage Temperature-25 - 65 °C
- Storage Relative Humidity0 - 95 %
- Storage Elevation0-50000ft ( 0-15000meters )
Conformance
- ApprovalscUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, UL 60950, UL Listed, VDE, VCCI
- Standard warranty2 years repair or replace
Sustainable Offer Status
- RoHSCompliant
- REACHREACH: Contains No SVHCs
- Battery DirectiveCompliant
- Battery Notests_Battery_Notes